. 16-bit high performance industrial class controller
Type |
Name |
Functional description |
MCP-ESHC
400 |
MCP-ESHC
300 |
Control functions |
Control function at upper and lower entrance |
Running/ Stopping can be controlled at both the upper and lower entrance of the escalator |
Yes |
Yes |
Up/Down reversal function |
Running Up/ Running down of the escalator can be selected freely. |
Yes |
Yes |
Display of running direction |
Running direction can be displayed through the indicator at the entrance of escalator |
Yes |
Yes |
Photo-electric input status setting |
Photo-electric input status can be set, i.e. the set up of input status for NO/ NC. |
Yes |
Yes |
Humanized LCD operator |
LCD operator board provides not only the display of escalator’s speed, direction and status but also the parameter setting and fault indication, etc. |
Yes |
Yes |
Inspection control |
Escalator inspection control can be operated through the inspection handle. |
Yes |
Yes |
Energy saving mode |
When no passenger approach the escalator within a presetting period, the escalator will run in low speed or rest for saving energy. Escalator entrances should be provided with photo-electric detectors. |
Yes |
No |
Soft braking |
In case no passenger approach the escalator within a presetting period and the escalator speed reduces to0.2m/s or below, the brake system will operate.
This braking method can reduce the wearing of the brake device. |
Yes |
No |
Emergency braking |
For super high-rise escalator, emergency brake is applied when over speed, reverse running, breakage ofdrive-chain, slip of still escalator is detected |
Yes |
Yes |
Automatic lubrication |
User can setup the time interval between automatic
lubrications, and also the consecutive time period in each lubrication. |
Yes |
Yes |
Protection against reversed direction entry |
During the escalator operating in energy saving mode, when passengers approach in a direction opposite to the escalator running direction, the escalator will alarm the buzzer immediately to alert the passenger. When no passenger approach the escalator after the presetting period, the escalator will resume to energy saving mode |
Yes |
Yes
|
Safety protection |
Protection against electric leakage |
Protection in case of overload, short-circuit and electric shock. |
Yes |
Yes |
Protection against phase loss and phase reversal |
The escalator will stop automatically during phase loss or phase reversal |
Yes |
Yes |
Protection device for electric loop |
Automatic circuit cut off device is provided to protect the circuit and power supply components of escalator. |
Yes |
Yes |
Protection against reverse running |
The escalator will stop when it has unintentional reverse running. |
Yes |
Yes |
Emergency stop button |
Stop the escalator unconditionally through that button |
Yes |
Yes |
Protection against drive chain breaking |
The escalator will stop when drive chain is elongated or broken. |
Yes |
Yes |
Protection against overload |
The escalator will stop when the running current is greater than the rated current |
Yes |
Yes |
Brake button at upper and lower terminal of the escalator |
Operation panel with brake buttonis provided on the skirting panel of upper and lower entrance of the escalator. |
Yes |
Yes |
Step chain safety protection |
The escalator will stop when the step chain is elongated or broken. |
Yes |
Yes |
Step operation safety protection |
The escalator will stop when the step is sagging, deformed or broken. |
Yes |
Yes |
Protection against upthrust of step |
The escalator will stop when foreign bodies being trapped between steps and the steps are upheaved |
Yes |
Yes |
Protection against sagging of step |
The escalator will stop when step roller is worn or foreign bodies being sandwiched. |
Yes |
Yes |
Skirting panel protection |
The escalator will stop when foreign bodies being trapped between the step and the skirting panel |
Yes |
Yes |
Comb teeth protection |
The escalator will stop when foreign bodies being trapped between the step and the comb teeth and may possibly damage the comb teeth. |
Yes |
Yes |
Handrail entrance protection |
The escalator will stop when foreign bodies being trapped inside the handrail entrances. |
Yes |
Yes |
Protection against handrail breakage |
The escalator will stop when the handrail is broken. |
Yes |
Yes |
Protection againstupper/ lower inspection mode actuated simultaneously |
Prohibit the escalator from operation when the inspection modes at upper and lower landing are actuated simultaneously. |
Yes |
Yes |
Monitoring functions |
Protection against contactors being stuck |
Prohibit the escalator from operation when the operating contactor and the braking contactor are being stuck |
Yes |
Yes |
Braking switch inspection |
Through the examination of the brake switch to determine whether the brake is normally open or released and to take corresponding measures. |
Yes |
Yes |
Monitoring of over peed and under speed |
The escalator will stop when the escalator speed is over or under the rated speed |
Yes |
Yes |
Monitoring of handrail speed |
The escalator will stop when the handrail speed is higher or lower than the step speed. |
Yes |
Yes |
Protection against lacking/damagingof steps |
The escalator will stop when lacking or damaging of escalator steps is detected. |
Yes |
Yes |
Automatic display of fault |
Automatically diagnose and display the faultson LCD. |
Yes |
Yes |
Safety switches monitoring |
Monitorevery safety switch and display their status on LCD of the main board, which is convenient for fault inspection in the field.
|
Yes |
Yes |
Group monitoring
In monitoring centre |
The user can monitor the operation status of every escalator in the monitoring escalator group on the computer of the monitoring centre, and fault alarming is also possible.
|
Option |
Option |
Remote monitoring
|
The user can remote monitor the operation status of the escalator through the use of telephone lines, and fault alarming is also possible.
|
Option |
Option |